 · The ActiveDSO control has 27 methods to aid in oscilloscope communications. Properties of an ActiveX control give users information. For example the ActiveDSO "ConnectionType" property can be called to determine if the scope is a GPIB, Network, or RS device. One of the more useful ActiveDSO properties is the "ErrorString" property. About this Manual This manual explains how to control the instrument from a computer, using commands keyed or programmed into an external controller. This controller is usually a computer, but it could be a simple terminal. The manual includes a complete list of the commands that you will need to perform remote control operations with the instrument. Teledyne LeCroy WaveRunner XI SERIES Operator’s Manual User Manual. W AVE R UNNER ®. X I SERIES O SCILLOSCOPES. Operator’s Manual. O CTOBER, LeCroy Corporation. Chestnut Ridge Road. Chestnut Ridge, NY – Tel: () .


It's not a version of LeCroy's ScopeExplorer(TM) or ActiveDSO(TM) software. Don't expect to compile the code, run it, and see the equivalent of your scope's screen appear on your PC monitor. What it does The code provided is simply a low-level driver for talking to a LeCroy instrument via TCP/IP, using the LeCroy VICP protocol. 示波器说明书. 便携式示波器中文说明书1、优利德科技 (成都)有限公司版权所有。. 2、本公司的产品受已获准及尚在审批的 大小:MB | 力科 (Lecroy)示波器操作手册 (中文完整版) 详细介绍了示波器原理、使用相关知识,对于从事高速硬件开发. Muon Lifetime Experiment MATLAB Script Documentation Sky Cheung1, 1Department of Physics, Columbia University, New York, NY USA (Dated: September 6, ) This contains a brief set of instructions for using LeCroy_Muon_Recorder.m to automatically collect.


About this Manual This manual explains how to control the instrument from a computer, using commands keyed or programmed into an external controller. This controller is usually a computer, but it could be a simple terminal. The manual includes a complete list of the commands that you will need to perform remote control operations with the instrument. A complete list % with variables can be found in the Xstream Browser which is run from the desktop of the oscilloscope % Users must make a manual connection to the oscilloscope. % First run: DSO = actxcontrol ('www.doorway.ruDSOCtrl.1', [0 0 ], gcf); % Load ActiveDSO control % Then right click on the black box in the figure and choose. The ActiveDSO control may be embedded in any OLE Automation compatible client and used manually without the need for any programming or scripting. The following simple example shows the control being embedded into a Microsoft PowerPoint slide.

0コメント

  • 1000 / 1000